Norlab

Your partner in Northern Europe for innovative laboratory instruments

Protein and phospholipid removal

Resource Type: 
Overview article
Author(s): 
Norlab
Format: 
Web Page
Date of creation: 
4 December 2015
Library code: 
10490

Effortlessly improve analyte sensitivity!

ISOLUTE PLD+ protein and phospholipid removal plates and columns provide a very effective but extremely simple sample clean-up for LC-MS/MS analysis. Requiring next to no method development, ISOLUTE PLD+ can be integrated quickly and easily into routine workflow, increasing productivity and reducing instrument downtime. ISOLUTE PLD+ plates and columns remove >99 % of plasma proteins and phospholipids, the main causes of ion suppression, leading to cleaner extracts and increased sensitivity (signal-to-noise (S/N)) for a broad range of analytes.

Remove more phospholipids and get better sensitivity

ISOLUTE PLD+ plates and columns deliver cleaner extracts than other phospholipid removal products, meaning lower detection limits can be achieved. In the example above, signal-to-noise using ISOLUTE PLD+ was more than double when compared with competitor products (figure 1), leading to an immediate enhancement in sensitivity. More than 99 % of phospholipids are removed as the sample passes through the multifunctional sorbent bed, leaving clean, purified extracts for analysis (figure 2).




Figure 1. Relative peak intensity, 20 pg/mL amitriptyline in plasma (Blue = ISOLUTE® PLD+, Orange = Competitor O, Red= Competitor P).




Figure 2. Levels of phospholipids present in plasma purified using protein precipitation (red and green), and ISOLUTE PLD+ protein and phospholipid removal plates (purple and black). More than 99% of phospholipids are removed.

Removing phospholipids also improves analytical column lifetime, preventing the build-up of phospholipids over multiple injections, and maintaining analyte sensitivity over extended analytical runs.

Using a simple solvent crash/filtration based procedure (figure 3), proteins and phospholipids are simultaneously removed from plasma and other blood based samples while high, reproducible analyte recoveries are maintained.




Figure 3. Typical ISOLUTE® PLD+ procedure.

The optimized frit arrangement acts as a depth filter, efficiently trapping precipitated proteins, without blocking or plugging.

Trouble free processing

ISOLUTE PLD+ products have excellent flow characteristics, and do not plug or block during use. They can be processed easily using either positive pressure or vacuum based systems, and are compatible with most automated liquid handlers. Up to 96 x 1 mL volume tabless format columns can be processed on Biotage Pressure+ 96, Extrahera and VacMaster-96 systems using specially designed racks. This cost effective option is ideal for applications with variable sample numbers or for method development.