Norlab

Your partner in Northern Europe for innovative laboratory instruments

pdf

Analysis of alkylphenones using high pressure resistance and high performance column under high pressure at 120 MPa
In this application note, the Jasco X-LC system, including the optional UHPLC hardware, was applied to the quick analysis of alkylphenones under high pressure (120 MPa pressure) using high pressure resistance and high performance column.

High-speed analysis of ultraviolet absorbers in sunscreen by UHPLC with photodiode array detection
In this report, multi-component ultraviolet absorber used in a sunscreen was analyzed by UHPLC with a PDA detector that enables high-speed data acquisition of 100 spectra/sec.

High-speed analysis of veterinary drugs by UHPLC with photodiode array detection
In this report, 24 components were separated simultaneously by gradient method using the reversed phase ODS column of 2 mm particle and high sensitivity detection using PDA detector for UHPLC.

High-speed separation of steroid drug betamethasone utilizing X-LC
Jasco examined the utility of an X-PressPak C18S column (2.1 mm I.D. x 50 mm L.) packed with 2 um diameter packing material for the ultra high-speed separation of betamethasone.

High-speed separation of steroid drug cortisone acetate utilizing X-LC
Jasco examined the utility of an X-PressPak C18S column (2.1 mm I.D. x 50 mm L.) packed with 2 um diameter packing material for the ultra high-speed separation of cortisone acetate.

High-speed separation of disulfiram utilizing X-LC
Jasco examined the utility of an X-PressPak C18S column (2.1 mm I.D. x 50 mm L.) packed with 2 um diameter packing material for the ultra high-speed separation of disulfiram.

High-speed separation of tuberculosis medicines utilizing X-LC
In this application, Jasco examined the utility of an X-PressPak C18S column (2.1 mm I.D. x 50 mm L.) packed with 2 um diameter packing material for the ultra high-speed separation of rifampin, isoniazid, and pyrazinamide.

Ultra high-speed analysis of cold and sinus medicines by UHPLC with photodiode array detection
In this report, active ingredients contained in cold and sinus medicines are analyzed by UHPLC with PDA detection, which enables ultra high-speed data acquisition at the rate of 100 spectra/sec.

High-speed separation of components in cold medicine using X-LC
Jasco examined the applicability of an X-PressPak C18S column (2.1 mm.I.D. x 50 mm L.) packed with 2 um diameter packing material for the ultra-high speed separation of acetoaminophen, anhydrous caffeine, hesperidine, ethenzamide, tipepidine hibenzate, and apronalid.

Reproducibility of retention times and peak area in X-LC
In this technical note, Jasco examined the usefulness of an X-LC system utilizing an X-PressPak C18S column (2.1 mm.I.D. x 50 mm L.) packed with 2 um diameter packing material for the ultra-high speed separation by evaluating the reproducibility of retention time and peak area.