Protein aggregation study with ferritin using AF4-UV/Vis In this application note, results from the characterization of ferritin are presented, as an example for a protein which is forming aggregates.
Protein aggregation study BSA using AF4-UV/Vis This application note describes results from the FFF characterization of BSA, bovine serum albumin, as an example for a protein which is forming aggregates.
Kinetic study of aggregation of milk protein and/or surfactant-stabilized oil-in-water emulsions by sedimentation field-flow fractionation This study employed sedimentation field-flow fractionation (SdFFF) to monitor changes in particle size distribution of freshly prepared emulsions with varying weight contributions of sodium caseinate (SC) and whey protein concentrate (WPC).
Postnova SF2000 GS (Gravitational SPLITT) series SPLITT fractionation utilizes the well-controlled hydrodynamics found in thin cells and the simplicity and flexibility of an externally applied field. The high stability of flow leads to high resolution separations and reproducible results.
Postnova model 3700 DLS Zetasizer Nano The Postnova PN3700 DLS Zetasizer Nano brings you the practiality of a maintenance-free system with the versatilty to offer precision measurement for your laboratory's particle characterisation needs in a single compact unit. It allows determininig the particle size, the zeta potential and the molecular weight.
Postnova model 3700 DLS series High sensitivity online dynamic light scattering detector, special customized for use connected to field-flow fractionation (AF2000, CF2000 and TF2000).
Postnova PN3000 XPT optical particle sizing detector The PN3000 XPT is ideal for use in pharmaceutical technology, biotechnology, chemical and environmental applications.
Postnova NovaSEC system The NovaSEC system has a 21 Angle MALS detector and a four-capillary viscometer detector. The NovaSEC software is a powerful multi detector SEC software.
Extraction of malachite green, crystal violet and their leuco metabolites from salmon using QuEChERS and EVOLUTE CX for LC-MS-MS analysis This application note focuses on ease of use when compared to other methods and describes a QuEChERS based approach incorporating the use of aluminium oxide in enhanced dispersive SPE to reduce the levels of fat in the final extract.
Extraction of over-the-counter pharmaceuticals from water and sludge cake using ISOLUTE QuEChERS prior to LC-MS analysis This study investigates the potential of commercially available QuEChERS kits for the extraction and clean-up of a suite of common over-the-counter (OTC) pharmaceuticals from water and sludge cake. Extracts are analysed using LC-MS-MS.